AXIS#.IL.DI2T

Description

AXIS#.IL.DI2T is the output of the drive foldback algorithm in [%]. It is a representation of thermal load of the drive, also known as I2T, given in [%].

AXIS#.IL.DI2T=0% means the drive is at 0% thermal load and peak drive current can be applied. AXIS#.IL.DI2T=100% means the drive is at 100% thermal load and only continuous current can be applied.

Versions

Action Version Notes
Implemented 02-03-03-000

 

General Information

Type

Read Only

Units

%

Range

0 to 100%

Default Value

N/A

Data Type

Float

Stored in Non-Volatile Memory

No

Variants Supported

All variants are supported.

Fieldbus Information

EtherCAT CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDO Mappable

AXIS1.IL.DI2T

500ah

12h

Signed32

-

1000:1

Read only

No

AXIS2.IL.DI2T

510ah

12h

Signed32

-

1000:1

Read only

No

EtherNet/IP

ID

Instance

Attribute

Name

Data Type

Access

User Mappable

5825

1

5825 (0x16c1)

AXIS1.IL.DI2T

Signed32

Read Only

Yes

71361

2

5825 (0x16c1)

AXIS2.IL.DI2T

Signed32

Read Only

Yes

PROFINET

Parameter

PNU

Data Type

Access

Units

AXIS#.IL.DI2T

5825

Float

Read Only

-